Korean Journal of Radiology ; : 58-68, 2019.
Article in English | WPRIM | ID: wpr-719597

ABSTRACT

OBJECTIVE: To compare digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) in the detectability of breast cancers in patients with dense breast tissue, and to determine the influencing factors in the detection of breast cancers using the two techniques. MATERIALS AND METHODS: Three blinded radiologists independently graded cancer detectability of 300 breast cancers (288 women with dense breasts) on DBT and conventional FFDM images, retrospectively. Hormone status, histologic grade, T stage, and breast cancer subtype were recorded to identify factors affecting cancer detectability. The Wilcoxon signed-rank test was used to compare cancer detectability by DBT and conventional FFDM. Fisher's exact tests were used to determine differences in cancer characteristics between detectability groups. Kruskal-Wallis tests were used to determine whether the detectability score differed according to cancer characteristics. RESULTS: Forty breast cancers (13.3%) were detectable only with DBT; 191 (63.7%) breast cancers were detected with both FFDM and DBT, and 69 (23%) were not detected with either. Cancer detectability scores were significantly higher for DBT than for conventional FFDM (median score, 6; range, 0–6; p < 0.001). The DBT-only cancer group had more invasive lobular-type breast cancers (22.5%) than the other two groups (i.e., cancer detected on both types of image [both-detected group], 5.2%; cancer not detected on either type of image [both-non-detected group], 7.3%), and less detectability of ductal carcinoma in situ (5% vs. 16.8% [both-detected group] vs. 27.5% [both-non-detected group]). Low-grade cancers were more often detected in the DBT-only group than in the both-detected group (22.5% vs. 10%, p = 0.026). Human epidermal growth factor receptor-2 (HER-2)-negative cancers were more often detected in the DBT-only group than in the both-detected group (92.3% vs. 70.5%, p = 0.004). Cancers surrounded by mostly glandular tissue were detected less often in the DBT only group than in the both-non-detected group (10% vs. 31.9%, p = 0.016). DBT cancer detectability scores were significantly associated with cancer type (p = 0.012), histologic grade (p = 0.013), T and N stage (p = 0.001, p = 0.024), proportion of glandular tissue surrounding lesions (p = 0.013), and lesion type (p < 0.001). CONCLUSION: Invasive lobular, low-grade, or HER-2-negative cancer is more detectable with DBT than with conventional FFDM in patients with dense breasts, but cancers surrounded by mostly glandular tissue might be missed with both techniques.


Subject(s)
Female , Humans , Breast Neoplasms , Breast , Carcinoma, Intraductal, Noninfiltrating , Epidermal Growth Factor , Mammography , Retrospective Studies
2.
Modern Hospital ; (6): 764-766,769, 2017.
Article in Chinese | WPRIM | ID: wpr-612686

ABSTRACT

Objective To explore the diagnostic value of full-field digital mammography (FFDM) combined with digital breast tomosynthesis (DBT) in breast diseases.Methods 506 patients receiving mammary gland molybdenum target inspection from January 1, 2014 to December 31, 2014 were selected.The images from FFDM and DBT were analyzed, respectively.The breast imaging reports and pathological results were compared to investigate the sensitivity, specificity and accuracy of FFDM, DBT alone and combined use of DBT and FFDM.Results The results of preoperative mammography in the 506 women (bilateral breast) were as follows: FFDM combined with DBT detected 202 benign cases (39.9%) and 304 malignant cases (60.1%);FFDM alone detected 194 benign cases (38.3%) and 312 malignant cases (61.7%);DBT alone detected 187 benign cases (37.0%) and 319 malignant cases (63.0%).Pathologically, 214 benign cases (42.3%) were detected and 292 malignant cases (57.7%).In terms of the sensitivity, specificity and accuracy, The combined use of DBT combined with FFDM was the best, followed by FFDM alone and DBT alone.Conclusion The sensitivity, specificity and accuracy of FFDM combined with DBT for diagnosis are better than those of FFDM alone or DBT alone.

3.
Korean Journal of Radiology ; : 305-312, 2014.
Article in English | WPRIM | ID: wpr-203190

ABSTRACT

OBJECTIVE: To compare new full-field digital mammography (FFDM) with and without use of an advanced post-processing algorithm to improve image quality, lesion detection, diagnostic performance, and priority rank. MATERIALS AND METHODS: During a 22-month period, we prospectively enrolled 100 cases of specimen FFDM mammography (Brestige(R)), which was performed alone or in combination with a post-processing algorithm developed by the manufacturer: group A (SMA), specimen mammography without application of "Mammogram enhancement ver. 2.0"; group B (SMB), specimen mammography with application of "Mammogram enhancement ver. 2.0". Two sets of specimen mammographies were randomly reviewed by five experienced radiologists. Image quality, lesion detection, diagnostic performance, and priority rank with regard to image preference were evaluated. RESULTS: Three aspects of image quality (overall quality, contrast, and noise) of the SMB were significantly superior to those of SMA (p < 0.05). SMB was significantly superior to SMA for visualizing calcifications (p < 0.05). Diagnostic performance, as evaluated by cancer score, was similar between SMA and SMB. SMB was preferred to SMA by four of the five reviewers. CONCLUSION: The post-processing algorithm may improve image quality with better image preference in FFDM than without use of the software.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Algorithms , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/methods , Prospective Studies , Radiographic Image Enhancement/methods , Sensitivity and Specificity , Software
4.
Korean Journal of Radiology ; : 164-170, 2013.
Article in English | WPRIM | ID: wpr-15373

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of new and established full-field digital mammography (FFDM) systems. MATERIALS AND METHODS: During a 15-month period, 1038 asymptomatic women who visited for mammography were prospectively included from two institutions. For women with routine two-view mammograms from established FFDM systems, bilateral mediolateral oblique (MLO) mammograms were repeated using the new FFDM system. One of the four reviewers evaluated two-sets of bilateral MLO mammograms at 4-week intervals by using a five-point score for the probability of malignancy according to a Breast Imaging Reporting and Data System. The lesion type and breast density were determined by the consensus of two readers at each institution. The dichotomized mammographic results correlated with a final pathologic outcome and follow-up data. Receiver operating characteristic (ROC) curves, sensitivity, and specificity were compared in general and according to the lesion type and breast density. RESULTS: Of the 1038 cases, 193 (18.6%) had cancer. The areas under the ROC curve (AUC), sensitivity, and specificity of the established system were 0.815, 65.3%, and 90.2%, respectively. Those of the new system were 0.839, 68.4%, and 91.7%, respectively. There were no significant differences in the AUCs, sensitivities or the specificities in general between new and established systems (Ps = 0.194, 0.590, 0.322, respectively). We found no significant difference in these parameters according to lesion type or breast density. CONCLUSION: The new FFDM system has a comparable diagnostic performance with established systems.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Area Under Curve , Breast Neoplasms/pathology , Mammography/methods , Prospective Studies , ROC Curve , Radiographic Image Enhancement/methods , Republic of Korea , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL